Voc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing Chamber

Product Details
Customization: Available
After-sales Service: 1 Year
Power Supply: AC 380 V

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
9900000 RMB
Plant Area
>2000 square meters
  • Voc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing Chamber
  • Voc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing Chamber
  • Voc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing Chamber
  • Voc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing Chamber
  • Voc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing Chamber
  • Voc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing Chamber
Find Similar Products
  • Overview
  • Product Description
  • Fulfill the Standard
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
HYVD
Certification
CE, TUV, ISO
Warranty
1 Year
Relative Positive Pressure
10±5PA
Air Velocity
0.1~1.0m/S(Continuously Adjustable)
Air Exchange Volume Measurement
Electronic Flowmeter
Observation Window
330*450mm(W*H), Two
Transport Package
Strong Wooden Case
Specification
Customized
Trademark
HUANYI
Origin
China
HS Code
9013809000
Production Capacity
10000pieces/Year

Product Description

Product Description

VOC/aldehyde and ketone test environment chamber for automotive interior parts(sampling bag method) is mainly used to simulate different environmental temperature, humidity, and air exchange rate conditions. Automotive interior materials or products are placed in a testing chamber to test the VOC and formaldehyde emissions of automotive interior components under certain temperature, humidity, air exchange rate, and other conditions. VOC emissions of vehicle components are also tested under different conditions to control the toxic and harmful gas emissions caused by the components.


During the testing process, real-time monitoring of the background concentrations of formaldehyde, toluene, and total VOC is required. Under stable conditions where the concentration reaches the limit, sampling and testing are carried out to ensure the representativeness and effectiveness of the test data.
 

Fulfill the Standard

 

GB/T 27630-2011 Guidelines for the Best Evaluation of Air Quality in Passenger Cars

GB/T 31107-2014 General Technical Requirements for Climate Chambers for TestingVolatile Organic Compounds in Furniture

HU/7400 200 Methods for the formulation of sampling of volatile organic compounds and aldehydes and ketones in vehicles

JAMA Japan Automobile Manufacturers Association Voc Detection Method in Automobiles

10122192 1-2012 Interior Air of Road Vehicles-Part 1: Whole Vehicle Test-Specifications and Methods for the Determination of Volatle Organic Compounds in Cars

W PV3938 Overall Radiation Conditions of Automobiles Gases in the Interior Space of  Automobiles

T/0lIF13-2016 Regulations for the Evaluation of the Odor of the Air in Automobiles

VDA276 Automotive Standard

PV3942 Popular Standard

BMW GS 97014-3 BMW Standard

Product Parameters

 

Model HYVD-48 HYVD-24
Internal volume(m³) 48 24
Internal dimension W 6000 3000
D 4000 4000
H 2000 2000
Performance Temperature  Range 15ºC~85ºC
Volatilitty ≤±0.5ºC
Deviation ≤±2ºC
Background value(mg/m³) Formaldehyde: ≤0.02mg/m³; Acetaldehyde: ≤0.01mg/m³; Touluene: ≤0.02mg/m³
Ethlbenzene: ≤0.02mg/m³; Xylene ≤0.02mg/m³; Styrene≤0.002mg/m³; TVOC≤300μg/m³; Single VOC ≤20μg/m³
Relative positive pressure 10±5Pa
Air velocity 0.1~1.0m/s(continuously adjustable)
Air exchange volume measurement Electronic flowmeter
Temperature control method Electric heating, SCR load regulation module, forced hot air circulation
Observation window 330*450mm(W*H) , two
Material Outer chamber Cold rolled steel sheet 0.8mm, surface eletrostatic spraying , white
Inner chamber SUS304 mirror stainless steel 1.2mm
Insulation High temperature  resistant material+polyrethane composite, thickness 100mm
Sealing material Sillicone (medical grade) or polytetrafluoroethylene
Power supply Three-phase five-wire+protective grounding
Installed capacity(kw) 35 23.5
Noise(dB) ≤65dB
Ambient temperature 5ºC~35ºC

 

Company Profile

Voc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing ChamberVoc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing ChamberVoc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing ChamberVoc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing ChamberVoc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing ChamberVoc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing ChamberVoc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing ChamberVoc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing ChamberVoc /Aldehyde and Ketonr Test Environment Chamber for Automotive Interior/ Automotive Volatile Organic Compound (VOC) Testing Chamber