High temperature and low pressure test chamber is still a kind of precise and valuable equipment. The correct use and operation of the high and low testing machine can not only provide accurate basis for the detection personnel, but also make the environmental testing equipment run normally for a long time and extend the service life of the equipment.
Vacuum System of High Low Temperature Low Pressure Test Chamber
1. Composition of vacuum system: vacuum system is a part of obtaining vacuum degree and measuring and controlling vacuum degree, which is composed of vacuum measuring system and vacuum obtaining unit
2. Vacuum degree measurement: the vacuum degree is measured by a pressure sensor. The vacuum gauge uses pressure strain to measure the vacuum degree. The measured data is a linear electrical signal, which can be directly input to the device controller for display and control
How to operate the high, low temperature and low pressure test chamber correctly
First of all, during the high and low temperature test, be familiar with the sample performance, test conditions, test procedures and test technology required for the test, the technical performance of the test equipment used, the structure of the equipment, especially the operation and performance of the controller. Carefully read the operation manual of the test equipment, so as to avoid damage to the test sample and incorrect test data caused by abnormal operation of the test equipment due to operation errors.
Secondly, the high and low temperature and low pressure test chamber should reasonably select the high and low temperature test equipment. In order to ensure normal test, appropriate test equipment should be selected according to different conditions of test samples, and a reasonable proportion should be maintained between the effective volume of test samples and test chambers. For the test of heating test sample, its volume shall not be greater than one tenth of the effective volume of the test chamber. The volume of the non heating test sample shall not be greater than one fifth of the effective volume of the test chamber.
For example, when a 21 ` color TV is conducting temperature storage test, a test box with a volume of one cubic meter can meet the requirements, but when it is powered on, it cannot meet the requirements. It should be replaced with a larger test box, because the TV will emit heat when it is working.
Third, place the test samples correctly in the high, low temperature and low pressure test chamber. The test samples shall be placed more than 10cm away from the box wall, and multiple samples shall be placed on the same plane as far as possible. The sample shall be placed without blocking the air outlet and return air outlet, and a certain distance shall be reserved for the temperature and humidity sensor. To ensure the correct test temperature.
Specification | ||||||
Model | HYH-80D | HYH-150D | HYH-225D | HYH-408D | HYH-800D | HYH-1000D |
Inner Size(cm) (W x D x H) |
40×50 ×40 | 50×60×50 | 50×75×60 | 60×85×80 | 80×100×100 | 100×100×100 |
Outer Size(cm) (W x D x H) |
70x95x150 | 105x110x170 | 105x120x185 | 115x140x195 | 155x140x210 | 155x160x210 |
Weight(kg) | 160kg | 220kg | 300kg | 550kg | 960kg | 1100kg |
Standard parameter | Temp.control method | PID temperature humidity balance control | ||||
Temp.Range | -70ºC ~150ºC | |||||
Humid.Range | 20%~98%RH | |||||
Temp.Uniformity | ±2ºC | |||||
Temp.Fluctuation | ±0.5ºC | |||||
Humid.Uniformity | ±3%R·H | |||||
Heating Rate | ≥3ºC/min | |||||
Cooling Rate | ≥1~1.5ºC/min | |||||
Cooling Method | Air cooled | |||||
Material | Inner | SUS# 304 stainless steel 1.2mm | ||||
Outer | Cold-roll steel sheet with Electrostatic coating or SUS# 304 stainless steel | |||||
Insulation | Ultra-fine glass fiber insulation cotton / rigid polyurethane foam | |||||
Configuration | Heater | Ceramic heater | ||||
Humidifier | Stainless steel armour humidifier | |||||
Cooling | Mechnical single stage refrigeration | |||||
Compressor | Original imported French Tecumseh hermetic compressor | |||||
Other function | Running error ; self diagnosis ; breakdown tips ; auto-power off | |||||
Safety protection | Protection for compressor | Overload protection;overheat protection ; over pressure protection | ||||
Protection for chamber | dry burn alarm;water shortage alarm;electric leakage protection; | |||||
Protection for fan | Overload protection;phase sequence protection | |||||
Programmable Controller |
Brand | Standard TATO 7" LCD touch screen , optional Sanwon TEMI series | ||||
Language | Standard English interface, other language is optional | |||||
Resolution | Temperature:0.01ºC;Humidity:0.1%R·H | |||||
Program capacity | 269patterns/ 13450 segments | |||||
Running method | Fix mode & program mode | |||||
Power Supply | AC 380V @50Hz three phase |